Seitenansicht 39
Case Drain Filter
The PT machines are also equipped with a filter in the
auxiliary circuit case drain line. It protects the main
hydraulic system in the event of catastrophic failure in
an attachment. This filter is designed to last the life of
the vehicle. The only instance where this filter should
be replaced is if an attachment equipped with a case
drain has a drive motor failure during use. (fig. 4-62)
Fuse Panel
The electrical systems in the PT machines are
equipped with fuses that protect the electrical compo-
nents from damage. They are located on the fuse
panel behind the access cover on the lower right side
of the cab interior. (fig. 4-63)
In the event of an electrical malfunction, the most logi-
cal place to start is at the fuse panel. Check the fuse
related to the problem you are having and inspect it. If
the fuse appears black and burned, it needs to be
replaced. Replace fuses with the correct amperage
replacement fuse only. Replacing a fuse with one of a
lower amperage rating may lead to premature fuse fail-
ure. Replacing a fuse with one of a higher amperage
rating may burn out the electrical component the fuse
was meant to protect. See the troubleshooting section
in this manual for an additional resource to aid in track-
ing suspected electrical problems.